A comparison of overground and treadmill running for measuring the three-dimensional kinematics of the lumbo–pelvic–hip complex

Anthony G SchacheaCorresponding Author Informationemail address, Peter D Blanchb, David A Rathc, Tim V Wrigleyd, Roland Starre, Kim L Bennella

Received 24 August 2000; accepted 15 June 2001.

Abstract 

Objective. To compare overground and treadmill running for differences in the three-dimensional angular kinematics of the lumbo–pelvic–hip complex.

Design. A within-subject repeated measures design.

Background. The treadmill is an attractive research instrument as speed and slope are easily controlled and the required calibration volume is reduced. However, the degree to which treadmill running simulates overground running has not been resolved in the literature to date.

Methods. 10 able-bodied subjects ran overground and on a treadmill at a self-selected speed. The treadmill speed was matched to each subjects respective average overground speed. The time–distance and the three-dimensional angular kinematic data were captured using a passive marker based motion analysis system. A set of angular and temporal kinematic parameters were extracted from the data and subjected to statistical analyses.

Results. Significant differences were found between overground and treadmill running for all the time–distance parameters. Despite this, the kinematics of the lumbar spine and pelvis were similar between the two running conditions, with only three parameters being significantly different. These were lumbar extension at initial contact, anterior pelvic tilt at initial contact and the first maximum anterior pelvic tilt. Hip flexion-extension parameters were also only found to display subtle differences. Of the 17 hip parameters analysed, only hip flexion at initial contact, maximum hip flexion at loading response, hip extension at toe off, maximum hip extension and hip flexion-extension range of motion were found to be significantly different.

Conclusion. A high powered treadmill with a minimal belt speed fluctuation is capable of being used to obtain a representation of the typical three-dimensional kinematic pattern of the lumbo–pelvic–hip complex during running.Relevance

In order for the treadmill to be accepted as a useful research and/or clinical assessment instrument, it must be demonstrated that it does not significantly alter the performance of the evaluated activity. In this respect, a treadmill with minimal intra-stride belt speed variability and similar surface stiffness to the relevant overground condition is likely to be capable of being used to obtain a representation of the typical human running action for well accommodated subjects.

a Centre for Sports Medicine Research and Education, School of Physiotherapy, The University of Melbourne, Victoria 3010, Australia

b Department of Physiotherapy, Australian Institute of Sport, Australian Capital Territory, Australia

c Department of Biomechanics, Australian Institute of Sport, Australian Capital Territory, Australia

d Centre for Rehabilitation, Exercise and Sport Science, Victoria University of Technology, Victoria, Australia

e Hugh Williamson Gait Analysis Laboratory, The Royal Children's Hospital, Victoria, Australia

Corresponding Author InformationCorresponding author

PII: S0268-0033(01)00061-4


View previous. 5 of 14 View next.